1 product overview
YET846-WIFI(smart built-in tubular motor controller) is a Multi-Control intelligent controller with WIFI and RF 433M as the core. It can control the opening, stopping, and closing of curtains through long-range wireless remote control.; The product has the functions of upper and lower limit detection, working status detection, power outage memory, etc.. The product has a variety of working modes.
This product is mainly used in various kinds of electric curtain Windows, electric curtain doors, electric sunshade rolls and other application fields.

 

YET846 PC-WIFI smart built-in tubular motor controller

 

2 product characteristics
Support WiFi Intranet or Extranet connection: can be used as a single product or group network[multi-product] control;
Support on power access to the network technology: simple and convenient access to the network;
We support RF433 wireless control and facilitate more applications;
Support upper and lower limit detection and roll curtain working status detection function: such as up, down or stop of roll curtain, so that remote control is safer;
Support for self-locking and ticking two working modes;
Support power outage memory function;
Support RF remote control one-to-many control methods, group switch multiple devices(this function only for RF remote control with channel configuration function);
RF remote control has high confidentiality, stable performance, low power consumption and simple installation: simple to use, safe and reliable.

 

YET846 PC-WIFI smart built-in tubular motor controller

 

3 product specifications parameters

Input voltage AC100V-AC240V
Output voltage AC100V-AC240V
Wireless standard IEEE 802.11 b/g/n
Working frequency 2.4 G to 2.5 G(2400M to 2483.5 M) Hz / 433.92 MHz
Encryption Type WEP/TKIP/AES
Security mechanism WP/WPA2
Receive sensitivity 802.11 B: -91 dBm(11Mbps)

802.11 g: -75 dBm(54 Mbps)
802.11 N: -72 dBm(MCS7)

Static current <0.015A  (@220VAC)
Working current <0.015A  (@220VAC No motor)
Working environment Temperature: -40 °C ~ +80 °C Humidity: 20 % ~ 93 %
Storage environment Temperature: -20 °C ~ +70 °C Humidity: 20 % ~ 93 %
RF remote control code With 1527 yards of remote control
Remote control can be added 80(maximum number)
Size 98 * 27 * 22(mm)

 

4 product usage instructions
4.1 Simple plan of product size and connection:

 

YET846 PC-WIFI smart built-in tubular motor controller

 

YET846 PC-WIFI smart built-in tubular motor controller

 

Note:
Red Line: AC _ L connected to AC power supply;
Blue line: zero line AC_N connected to AC power supply;
Brown wire: Upstream of the connecting motor;
Black wire: the downlink of the connecting motor;
RF433 external antenna: used to enhance RF433 wireless reception signal;
WIFI external antenna: used to enhance Wi-Fi wireless reception signals;

 

4.2 Operating instructions for RF remote control
4.2.1 RF Remote control interface description

 

YET846 PC-WIFI smart built-in tubular motor controller

 

Note:
Channel display: The number 01-15 can be displayed for 1-15 channels, the letter PP is expressed as a public channel, and all devices installed on the PP channel, The function of group switching can be achieved(ie, all devices are fully open or closed or stop);
The roll curtain lift key, roll curtain drop key, roll curtain stop key: for the realization of roll curtain open, close and stop;
Channel key increase, channel key reduction: used to select different remote control channels;
Remote control code P key: for adding equipment;

Note:
In the above, the “roll up key” and “roll down key” are only described functionally in this manual. In different applications, there may be different naming methods for the same key. For example: “uplink / open key”, “downlink / off key”, etc., please refer to the naming method of the corresponding key in this manual to understand the use of the remote control in practical applications.
This remote control as the product’s Fangbiao accessories, if users want to use the remote control other than this remote control to control this product, please use the use of the relevant after-sale customer service to facilitate access to technical support.

 

4.2.2 Description of functions of RF remote control
Set remote control channel
Before adding a new device with the RF remote control, you need to assign a remote control channel value to the new device, which can be any channel value in 01-15, or it can be configured as a PP channel. The specific operations are as follows:
Press the channel to increase the key, the channel from 01 to 15, PP increase;
Press the channel key, the channel decreases from 15 to 01, PP;

Remote control learning(ie, frequency or code):
When the product is on the electricity, the buzzer rings once, indicating that the electricity is successful and enters the learning mode. At this time, press any key in the ‘roll up key’ or ‘roll down key’ on the remote control. The buzzer on the product is short. Ring 2 times, Indicate success in learning; Otherwise, the buzzer on the product grows 1 time, indicating failure of learning.
When you enter the learning state for 15 seconds, if you do not succeed in learning, the buzzer on the product will ring once, indicating that you have failed in learning or give up learning automatically.

Clear single RF remote:
After the electricity on the product is ready to work, the roll curtain stop key on the RF remote control to be deleted is pressed until the buzzer on the product is released after two consecutive short rings, indicating that the single RF remote control has been deleted successfully; Otherwise, the buzzer on the product grows once, indicating that the deletion failed.

Clear all RF remote controls:
After the electricity on the product is ready to work, when the remote control code P key on the back of the remote control(bottom shell) is long pressed, until the buzzer on the product is released after two consecutive short rings, indicating that all RF remote controls have been deleted successfully; Otherwise, the buzzer on the product grows once, indicating that the deletion failed.

Remote control, turn off.
Short press roll up key: execute roll up action.
Short press roll curtain drop key: execute roll curtain drop action.
Press Curtain Stop Key: Curtain stop running.

Switching motor direction
After waiting for the normal work on the product, press the ‘channel increase key + roll curtain stop key’ combination key on the RF remote control at the same time, until the buzzer on the product is released after two consecutive short rings, indicating the success of the switch; Otherwise, the buzzer on the product grows 1 time, indicating that the change has failed.
Remarks: The reversing operation must be completed within 15 seconds. If the operating time exceeds 15 seconds, the current function setting is withdrawn. You need to follow the above steps again.

Unlock and lock
Lock: After the product is on power to work, select the channel parameter value currently configured for the product. At the same time, press the ‘channel increase + channel decrease key’ until the buzzer on the product rings twice in a row, that is, the lock is successful. At this time, the remote control can no longer control the rise or fall of the curtain;
Unlock: Select the channel parameter value currently configured for the product, and press the ‘channel booster + channel dimmer’ until the buzzer on the product rings twice in a row, which means the unlock is successful. At this time, you can normally control the roll curtain. Rise or fall.

Settings for the click mode
If the current working mode is self-locking mode(the factory default is self-locking mode), if you want to set it to point mode, press the learned remote control ‘channel key reduction + roll curtain stop key’. Key combination key 5 seconds or more, When the buzzer on the controller rings twice, the click mode setting is successful; Otherwise, the buzzer on the product grows 1 time, indicating that the setting fails.

Settings for self-locking mode
After the power on the product is ready to work normally, if the current working mode is point mode, if you need to set it to self-lock mode, you must press the learned remote control ‘channel subkey + roll curtain stop key’ combined key for more than 5 seconds. After the buzzer on the controller rang short twice, Indicates that the self-locking mode setting was successful; Otherwise, the buzzer on the product grows 1 time, indicating that the setting fails.

 

4.3 Remote control
4.3.1 Download and installation of APP software:
Android system:
Domestic users: Users can search keywords through the “Application Store _ 360 Mobile Assistant” platform: “Yaoertai”, “Safe”, download the latest version of “safemate.apk” software, and complete the installation of APP software as prompted;
Overseas users: Users can use the “Google Play” platform to search for keywords: “Yaoertai”, “Safe”, download the latest version of “safemate.apk” software, and complete the installation of APP software as prompted;
iOS system: Domestic and foreign users can use the “App Store” platform to search for keywords: “Yaoertai”, “Safe”, download the latest version of “Safe” software, and complete the installation of APP software as prompted.
Users can also download and install by scanning the lower two-dimensional code:

                    

Android(Chinese user)            Android(other countries and regions user)              IOS user

 

4.3.2 APP user registration and login
Account Registration:
Click on the registration button of the login page to enter the registration page.

 

YET846 PC-WIFI smart built-in tubular motor controller       YET846 PC-WIFI smart built-in tubular motor controller

Please click on the country/region to enter the country/region page and select your country or region; Return to the registration page, type your correct mobile phone number, and click to send the verification code; Enter the verification code you received on your phone in the verification field; Before clicking on the next step, you need to read the product disclaimer and check that I have read and agreed to the disclaimer; After the validator check has passed, click next to enter the user information configuration page.

YET846 PC-WIFI smart built-in tubular motor controller       YET846 PC-WIFI smart built-in tubular motor controller

 

In the user information configuration page, fill in your mailbox address, login password, and fill in the login password again; After confirming that all the information is correct, click the Finish button and the system will remind you that you have registered successfully; Click OK, the system automatically returns to the login page, when you can use your account password to log on to this software system.

 

YET846 PC-WIFI smart built-in tubular motor controller       YET846 PC-WIFI smart built-in tubular motor controller

Logging in account:
You must use your account to log in before you can manage and operate your device; The login method is divided into two ways: mobile phone and mailbox. Enter the correct account number and password, click on login, and successfully log in to the home page of the system.

 

YET846 PC-WIFI smart built-in tubular motor controller       YET846 PC-WIFI smart built-in tubular motor controller

 

4.3.3 APP User Manual
Run APP software, enter the personal center page; Click on the user’s manual to enter the user’s manual page, where you can choose what you want to know about the operation;
Account management: You will be introduced to “new account registration, account login, password management, Mailbox configuration” and other content;
Equipment management: will introduce to you “add new equipment, equipment classification, equipment list information” and other content;
Location management: “Add new location, edit location, device location change or delete” will be introduced to you;
Device control: will introduce you to the “device specific operation application” and other content;
Attention: you will be introduced to the use of equipment needs to pay attention;

 

      YET846 PC-WIFI smart built-in tubular motor controller

 

4.3.4 Product handling
One button into the net:
You must log in with your account before adding your new device:
Click on Add Device to select add device mode. Select add device mode according to the new device’s wireless communication mode.

 

YET846 PC-WIFI smart built-in tubular motor controller      YET846 PC-WIFI smart built-in tubular motor controller

 

Into the one-key configuration page, enter the Wi-Fi password for the current wireless network, and click OK to enter the network mode; At the same time, the key on the new device is pressed three times in a row. At this time, the indicator light on the device continues to flash to indicate that the device enters the network mode; The new device may take you a few seconds or more to access(depending on the current wireless Wi-Fi environment). After successful access to the network, the indicator on the device becomes slow flash, APP terminal display adds device successfully.

 

YET846 PC-WIFI smart built-in tubular motor controller     YET846 PC-WIFI smart built-in tubular motor controller

 

Product master page:
When you successfully add a new device, click on the added device to enter the following master page of this product; At this point, you can enjoy the fun and convenience of this smart product.

 

YET846 PC-WIFI smart built-in tubular motor controller      YET846 PC-WIFI smart built-in tubular motor controller

 

5, frequently asked questions
Question 1: failed to add device, the product signal indicator light has been slow flashing?
The slow flashing of the signal indicator indicates that the router is being connected. When the connection time exceeds 60S, the connection fails. This situation may be “Wi-Fi password input error” or “data error during transmission”; Users need to check the status of the mobile phone or Wi-Fi router network, and make sure that the router Wi-Fi has no connection restrictions and try to reconfigure it again.

 

Problem 2: Suddenly the equipment is out of control
A, check whether the router Wi-Fi password has changed, see the device signal indicator status, if it is a slow flash description and the router disconnected, reconfigure on;
B, the IP address assigned to the device by the router causes the IP address to change due to network reasons, resulting in the device’s actual IP and the device IP saved by APP are inconsistent. At this time, exit the APP and restart, and regain the device information.

Did you find apk for android? You can find new Free Android Games and apps.